Compensated Jacket Calorimeter

  • The LECJC-6050 Compensated Jacket Calorimeter is a compact static-jacket instrument operated from a personal computer. It works at room temperature and uses real-time temperature measurements to compensate for heat exchange.

    Operating arrangement

    • A conventional calorimeter layout uses an oxygen bomb and bucket that can both be removed.
    • Real-time temperature readings determine heat leakage without a temperature-controlled calorimeter jacket.
    • The calorimeter provides its operating functions without requiring circulating water.
    • The compact enclosure keeps the required laboratory bench area small.
    • A USB connection links the instrument to the PC.

    The measurement method applies continuous correction in real time. Jacket temperature is monitored throughout the test. Heat-leak corrections follow the difference between the bucket temperature and the actual measured jacket temperature, rather than relying on a controlled jacket temperature.

    This description defines the product family. Guaranteed performance, included hardware, exclusions, interfaces and acceptance criteria are stated only in the project-specific technical proposal and approved datasheet.

    • Compensated Jacket Calorimeter
    • Compensated Jacket Calorimeter
    • Compensated Jacket Calorimeter
  • Operation and control

    • PC operation: connect the calorimeter to a Windows PC with a standard USB cable. The calorimeter software is installed on the user's PC and provides mouse access to every function and test.
    • Automatic oxygen charging: before each test, the instrument fills the combustion vessel with the required oxygen quantity. This automatic function replaces a manual operation during normal vessel preparation.
    • The instrument runs at room temperature.
    • A test takes 8 minutes in Dynamic Mode or 12 minutes in Equilibrium Mode.

    Instrument specifications

    • Calorimetry using a compensated jacket
    • Removable oxygen vessel and removable bucket
    • Throughput: 4-6 tests per hour
    • Operator involvement: approximately 6 minutes per test
    • Instrument precision class: 0.2%
    • Resolution of temperature measurement: 0.0001 °C
    • Maximum energy released in one test: 10000 calorie
    • Linearity throughout the operating range: 0.05%
    • PC communication through a USB port
    • Software updates available through the Internet
    • Overall dimensions (in): 10.5w x 17.5d x 16.5h
    • Overall dimensions (cm): 27w x 45d x 42h
  • Extended calorimeter package

    The extended package comprises the following items. The table also identifies accessories available in addition to that package.

    Extended package contents
    ComponentEquipment description
    CalorimeterCalorimeter with a compensated jacket
    Combustion vesselAdditional oxygen combustion vessel
    BucketAdditional calorimeter bucket
    Service kitService kit covering 1 Year
    Further accessory options
    Combustion vesselAdditional vessel for oxygen combustion
    Sulfur-service vesselAdditional oxygen combustion vessel for sulfur service
    Chlorine-service vesselAdditional oxygen combustion vessel for chlorine service
    BucketAdditional calorimeter bucket
    Spare partsKit of replacement parts
    Gas collectionKit containing the gas collection assembly
    Pellet pressPellet press supplied with a 1/2 in punch and die