Equilibrium Flash Separator

  • The LEEFSA equilibrium flash separator flashes a pressurized liquid sample in a two-stage arrangement and measures the gas-oil ratio (GOR) at equilibrium. PVT and phase behavior laboratories use it to split a live oil sample into liberated gas and stock-tank liquid and to calculate GOR from the two measured volumes.

    How it works

    The pressurized sample is flashed through two stages. Stage pressure and temperature are controlled, so each stage reaches equilibrium at known conditions. The gas liberated in the flash is collected in a gasometer and its volume is measured at ambient conditions. The liquid is collected in a graduated tube and its volume is read directly. GOR is calculated from the gas volume and the liquid volume.

    The cell volume is 40 cc and the working pressure range is from vacuum to 500 psi. Liquid volume is read with an accuracy of 0.1 ml. Wetted parts are Pyrex and stainless steel, so the liquid level can be seen during the test. The sample can be heated with an external heating fluid when the flash must be run above ambient temperature.

    Key data

    • Volume: 40 cc
    • Pressure: vacuum to 500 psi
    • Volume accuracy: 0.1 ml
    • Wetted parts: Pyrex, stainless steel
    • Power supply: 220 VAC, 50 Hz

    What is measured

    • Liberated gas volume, by gasometer at ambient conditions
    • Liquid volume, in a graduated tube
    • Calculated GOR

    Specify for your project

    • Sample type and the flash pressure needed, up to 500 psi
    • Stage temperatures, and whether the external heating fluid circuit is needed
    • Expected gas volume, to size the gasometer
    • Wetted material requirements beyond Pyrex and stainless steel
    • Power supply if different from 220 VAC, 50 Hz

    Cell volume, pressure and temperature ratings, wetted materials, visual and measurement options and instrumentation are configured per project.

    This description defines the product family. Guaranteed performance, included hardware, exclusions, interfaces and acceptance criteria are stated only in the project-specific technical proposal and approved datasheet.

    • Equilibrium Flash Separator
  • Features

    • Volume : 40 cc Pressure : vacuum to 500 psi
    • Volume accuracy : 0.1 ml
    • Wetted parts : Pyrex, stainless steel
    • Power supply : 220 VAC ,50 Hz

    Benefits

    • Easy operation
    • Accurate liquid volume measurement
    • Possibility to heat sample with an external heating fluid
Coretest