✓ In-house manufacturing — Hastelloy C276 & titanium✓ Custom engineering & prototypes✓ API / ASTM · CSA · CRN · CE✓ Serving US, Canada, EU, Middle East, Central Asia, Africa & LatAm

Sample Restoration Apparatus

  • The Sample Restoration Apparatus (CT-PVA-SRA) brings a reservoir fluid sample, still in its sample cylinder, back to reservoir-representative pressure and temperature before it is transferred to a PVT cell or other analysis. It belongs to the PVT accessories group together with gas boosters, pressure generators and heated cylinder trolleys. The unit heats and agitates the mounted cylinder and regulates temperature from ambient to 200 °C.

    How it works

    The sample cylinder mounts directly in the apparatus, and the unit is portable. Cylinders of 80 to 100 mm diameter and 500 to 750 mm length are accepted as standard, other sizes on request. Heating raises the cylinder to the set temperature with a stated accuracy of ±5 °C, and agitation keeps the sample mixed while it is held at conditions. Pressure restoration is controlled in parallel. The restored pressure and temperature are the reported conditions of the sample.

    The pressure rating and the pressurizing method are project-dependent. Power supply is 220 VAC, 50 Hz.

    What is included

    • Heated cylinder holder with agitation
    • Temperature regulation, ambient to 200 °C, accuracy ±5 °C
    • Cylinder mounting for 80 to 100 mm diameter and 500 to 750 mm length
    • Movable unit

    Specify for your project

    • Sample cylinder diameter and length (standard 80 to 100 mm and 500 to 750 mm; other sizes on request)
    • Restoration temperature within ambient to 200 °C
    • Restoration pressure and pressurizing method (project-dependent)
    • Sample type and wetted materials in contact with it
    • Instrumentation and data output required
    • Power supply if different from 220 VAC, 50 Hz

    This description defines the product family. Guaranteed performance, included hardware, exclusions, interfaces and acceptance criteria are stated only in the project-specific technical proposal and approved datasheet.

    Model: LESRA

    • Sample Restoration Apparatus
  • Features

    • Temperature range: ambient up to 200°C
    • Temperature accuracy: ± 5°C
    • Cylinder diameter: 80 to 100 mm (other sizes on request)
    • Cylinder length: 500 to 750 mm (other sizes on request)
    • Supply: 220 VAC, 50 Hz

    Benefits

    • Effective agitation
    • Quick heating
    • Very precise regulation
    • Simple to move
    • The cylinder mounts easily
Coretest