Thermal Abuse Test Chamber
Send a request
Thermal Abuse Test Chamber
The Thermal Abuse Test Chamber LEGTA-180 heats a single cell or a battery module at a controlled ramp to a set temperature and holds it while the specimen is observed. It is built for the heating tests of IEC 62133-2017, UL 1642 and GB 31241-2014. The chamber ramps from room temperature to 150 °C at a linear 5 °C/min, with ±0.5 °C control accuracy and ±2.0 °C deviation at no load.
How it works
The specimen is placed in the 600 × 500 × 600 mm working cabinet, wired through 50 mm terminal holes in the side walls, and the door is closed on an explosion-proof lock and chain. The 7 in PLC touch panel runs the profile. In the standard sequence, a charged lithium-ion cell is heated to 130 °C ± 2 °C at 5 °C/min, held for 30 minutes and then observed for 1 hour; nickel metal hydride cells are heated to 85 °C ± 2 °C and held for 2 hours. Test data are exported by USB.
The inner chamber is mirror-finish SUS304 stainless steel inside a 1.5 mm SECC steel shell with powder coating, insulated with high-density glass wool and high-temperature silicone seals. A 390 × 360 mm window of 20 mm explosion-proof glass with a mesh guard allows observation. An explosion-proof pressure relief device, smoke exhaust, explosion-proof lighting, electronic door lock and safety stop switch contain and vent an event. The cabinet is 940 × 780 × 1620 mm overall on casters and runs on 220 V, 50 Hz, 4.0 kW.
What is included
- LEGTA-180 chamber, all-in-one structure on universal wheels
- 7 in PLC touch controller, remote control, USB data export
- Explosion-proof window, pressure relief, smoke exhaust, lighting, electronic door lock and safety stop switch
- Two 50 mm terminal holes
Specify for your project
- Cell or module dimensions and mass against the 600 × 500 × 600 mm cabinet
- Test standard and profile: IEC 62133-2017, UL 1642 or GB 31241-2014, and the set temperature
- Number and size of cable feed-throughs beyond the two 50 mm ports
- Site power (220 V, 50 Hz, 4.0 kW) and exhaust duct connection
This description defines the product family. Guaranteed performance, included hardware, exclusions, interfaces and acceptance criteria are stated only in the project-specific technical proposal and approved datasheet.
Main Technical Parameters
Model LEGTA-180 Structure All-in-one structure, the door uses explosion-proof lock + explosion-proof chain Normal temperature to 150°C (Adjustable) Temperature Range Controlling Accuracy ±0.5℃ Temperature Deviation ±2.0℃, No load Heating Rate RT~150°C (Linear 5°C/min) Control Display PLC touch type (7 inch) + remote control Working Cabinet Dimension W600XD500XH600 mm External Dimension W940XD780XH1620 mm Inner Chamber Material SUS304 Stainless steel with mirror-finish External Chamber Material SECC steel plate, fine powder paint coating (thickness 1.5mm) Bottom With universal wheel Observation Window 390 X 360mm (20mm thick explosion-proof glass, explosion-proof mesh) Insulation Material Imported high-density glass wool, good heat insulation, to ensure maximum temperature insulation, tight sealing materials for high temperature resistant silicone, withstanding high temperatures over 300 degrees for a long time Terminal Hole Diameter 50mm Terminal hole on the left and right sides Power Supply 220V / 50HZ / 4.0KW USB Interface With USB interface, the test data can be exported Auxiliary Function Explosion-proof pressure relief device, smoke exhaust device, explosion-proof lighting device, electronic door lock system, safety stop switch The heating test of battery thermal abuse test chamber shall be carried out as follows
1. Relevant standard test requirements
- Single battery safety test
- The heating test is carried out as follows:
- The single battery is charged according to the method of 6.1.3
- Put the single battery into the temperature chamber.For lithium-ion batteries, the temperature chamber is increased from room temperature to 130 ° C ± 2 ° C at a rate of 5 ° C / min, and the heating is stopped after maintaining the temperature for 30 minutes.
- For nickel metal hydride batteries, the temperature chamber is raised from room temperature to 85 ° C ± 2 ° C at a rate of 5 ° C / min, and the heating is stopped after maintaining this temperature for 2h.
- Observe for 1h.
2.Battery module safety test
- The battery module battery shall be charged according to the method in 6.1.4.
- For lithium-ion batteries, the temperature chamber is raised from room temperature to 130 ° C ± 2 ° C at a rate of 5 ° C / min, and the heating is stopped after maintaining this temperature for 30 minutes.
- For nickel metal hydride batteries, the temperature chamber is raised to 85 ° C ± 2 ° C at room temperature at a rate of 5 ° C / min, and the heating is stopped after maintaining this temperature for 2h.
- Observe for 1h.