✓ In-house manufacturing — Hastelloy C276 & titanium✓ Custom engineering & prototypes✓ API / ASTM · CSA · CRN · CE✓ Serving US, Canada, EU, Middle East, Central Asia, Africa & LatAm

Flow Assurance System

  • The LEFLASS flow assurance system joins a reservoir fluid PVT cell and solid deposition testing in one setup. The same instrument runs standard PVT studies, constant mass expansion, differential vaporization and separator tests, and then asphaltene and wax experiments on the same sample. PVT and flow assurance laboratories use it to describe both the phase behaviour of a fluid and the conditions at which organic solids precipitate.

    How it works

    The sample sits in a cell of up to 200 cc with stainless steel and sapphire wetted parts. Cell pressure, up to 15,000 psi, and temperature, from ambient to 200 °C, are controlled, with a cooling option down to -20 °C for wax work. The deposition test sequence is run under the same control. Measured results are the PVT properties of the fluid together with asphaltene and wax onset and deposition.

    For asphaltenes, the system gives a full description of precipitation: pressure, temperature, growth and morphology of the solids. The sapphire in the wetted path allows visual observation of the sample during the test.

    Typical applications

    • Constant mass expansion
    • Differential vaporization
    • Separator tests
    • Asphaltene precipitation onset, growth and morphology
    • Wax onset and deposition with the cooling option

    Key data

    • Pressure: up to 15,000 psi
    • Temperature: ambient to 200 °C, cooling option to -20 °C
    • Cell volume: up to 200 cc
    • Wetted materials: stainless steel, sapphire

    Specify for your project

    • Maximum pressure, up to 15,000 psi
    • Temperature range, including the -20 °C cooling option if wax tests are planned
    • Cell volume, up to 200 cc
    • Test program: PVT tests, deposition tests or both
    • Measurement and data acquisition scope

    This description defines the product family. Guaranteed performance, included hardware, exclusions, interfaces and acceptance criteria are stated only in the project-specific technical proposal and approved datasheet.

    • Flow Assurance System
  • Technical data

    • The pressure limit for testing is 15,000 psi.
    • Tests run from ambient temperature to 200°C; optional cooling extends operation to -20°C.
    • The available volume reaches 200 cc.
    • Sapphire and stainless steel form the surfaces that contact the fluid.

    Operation and applications

    • The equipment supports phase-behaviour measurements as well as complete experiments on solids deposition.
    • Asphaltene precipitation can be characterized by its pressure, temperature, particle growth and morphology.