Cooling Coils for Stirred Reactors
Send a request
Cooling Coils for Stirred Reactors
LECCSR internal cooling coils remove heat from the contents of a stirred pressure reactor. The removable tube coils pass through the head and are available for all reactor sizes except the smallest. They control heat generated by exothermic reactions and lower the vessel temperature after a test.
Cooling operation and coil geometry
The coil is immersed in the process liquid while cooling medium passes through its tubing. Heat crosses the thin tube wall rather than the thick vessel wall. Cooling is therefore generally faster than heating, especially above 80 °C. Water is the usual coolant; compressed air can handle modest cooling duties.
Three standard geometries are available. The single loop design forms a vertical hairpin from one length of tube and fits small reactors with restricted space. The serpentine design distributes six to eight vertical tube runs around the vessel circumference. It provides useful heat transfer area with limited disturbance to stirring, adds some baffling, and remains accessible for cleaning and maintenance.
A spiral coil places several loops just inside the vessel bore. It provides the largest cooling surface, but can reduce mixing uniformity and make cleaning harder. Standard spiral coils serve vessels with 4 in and 6 in ID; other sizes can be made to special order. The reactor specification establishes which coil geometries can be installed.
Supply scope
- A cooling coil of the chosen geometry, made from the same material as the reactor body.
- On request, plugs for closing the head openings when the coil is removed.
Information for coil selection
- The reactor model, inside diameter of the vessel and head port arrangement.
- The required geometry: single loop, serpentine or spiral.
- The coil material corresponding to the reactor body alloy.
- The cooling medium, either water or compressed air.
- Any requirement to reuse the head openings as alternative inlets or outlets when the cooling coil is not needed.
This description defines the product family. Guaranteed performance, included hardware, exclusions, interfaces and acceptance criteria are stated only in the project-specific technical proposal and approved datasheet.
Three standard cooling coil arrangements are available for the reactors.
Single loop arrangement
A vertical length of tube is bent into a hairpin to form the single loop coil. This compact arrangement is normally fitted to small reactors, where little space is available for an internal cooling element.
Serpentine arrangement
The serpentine coil has six to eight vertical tube runs distributed evenly around the vessel circumference. It provides a useful cooling surface with limited disturbance to the stirring flow. The tube runs also supply a moderate baffling effect, while retaining convenient access for cleaning and maintenance.
Spiral arrangement
A spiral coil uses several loops wound close to the inside diameter of the vessel. Standard availability normally covers vessels with 4″ and 6″ ID; other sizes can be supplied as special orders. This form maximizes the available cooling area, although the extra tubing can reduce stirring uniformity and make cleaning less convenient.
The specification for each reactor identifies the coil arrangement or choice of arrangements available for that vessel.
Coils can be supplied in the same material options as the reactor bodies. Every cooling coil is removable. Head openings can be closed with plugs after a coil is taken out. In most cases, when internal cooling is not needed, those openings can instead be used as alternative inlet or outlet connections.