Drop Tester for Portable Gadgets
Send a request
Drop Tester for Portable Gadgets
The Drop Tester for Portable Gadgets LEGDP performs drop impact tests on smart phones, cell phones and other mobile gadgets. A specimen holding system keeps the dropping posture of the device so that the orientation at impact is repeatable and results are reproducible between runs. Devices are released from controlled heights onto defined surfaces, and the results guide housing design, cushioning choices and durability claims for consumer products before launch.
How it works
The device is fixed in the specimen holding system, which is held by an electromagnetic holder. The drop height is set on a scale between 250 and 2000 mm: by a manual scale and setting pointer on the LEGDP-2, or by an automatic scale and setting pointer on the LEGDP-275. A pneumatic pen cylinder holds and releases the specimen while keeping its posture, so the impact point can be controlled. As a safety measure the electromagnetic holder never releases the specimen holding system until it is energized.
The LEGDP-2 carries a payload of 2 kg on a 100 x 200 mm package size, measures 500 x 600 x 2382 mm and weighs 85 kg. The LEGDP-275 carries 7.5 kg on a 450 x 450 mm package size, measures 900 x 1100 x 2380 mm and weighs 430 kg. Both run on AC 220 V 50 Hz with a 5 kg/cm² air supply. The applicable standards listed for the family are JIS C 60068-0-31 and IEC 60068-2-31.
What is included
- Drop tower with height scale and setting pointer (manual or automatic by model)
- Specimen holding system with pneumatic pen cylinder
- Electromagnetic holder with energize-to-release safety
Specify for your project
- Specimen mass and size: LEGDP-2 (2 kg, 100 x 200 mm) or LEGDP-275 (7.5 kg, 450 x 450 mm)
- Drop heights and drop orientations required by the test plan
- Manual or automatic height setting
- Impact surface and fixture requirements
- Compressed air at 5 kg/cm² and AC 220 V 50 Hz supply
This description defines the product family. Guaranteed performance, included hardware, exclusions, interfaces and acceptance criteria are stated only in the project-specific technical proposal and approved datasheet.
Features
- Keep the dropping posture with pneumatic pen cylinder. The impact point can be controlled easily;
- The drop height can be settled flexibly by scale, and the specimen holding system is fixed firmly with the electromagnetic holder;
- Safety design-the electromagnetic holder never release the specimen holding system till it’s energized.
Technical Parameters:
Model LEGDP-2 LEGDP-275 Payload Capacity(kg) 2 7.5 Drop Height(mm) 250~2000 250~2000 Drop Height Setting Manual Scale and setting pointer Automatic Scale and setting pointer Holding/Releasing Specimen Pneumatic per cylinder Pneumatic per cylinder Package Size(mm) 100(W)×200(L) 450(W)×450(L) Machine Size(mm) 500×600×2382 900×1100×2380 Machine Weight(kg) 85 430 Power Supply AC220V 50Hz AC220V 50Hz Supply Air Pressure 5kg/C㎡ 5kg/C㎡ Applicable Standards JIS C 60068-0-31, IEC 60068-2-31 JIS C 60068-0-31, IEC 60068-2-31