Large Current Battery Short Circuit Test Equipment LEGSC

  • Application

    Battery Module, Battery Pack, Battery System short circuit.

    Short Circuit Mode

    Pneumatic drive contact + Vacuum InterrupterTesting Standard/IEC 62619.

  • Relevant standards requirement

    1. Test object: battery pack and system

    2. Test conditions:

    • The test temperature should be at 20±10℃or higher. (According to the battery system manufacturer’s request).
    • All protective Equipments that affect the function of the test objects and related to the test results shall be in normal operation when the test starts.

    3. The main contactors used for charging and discharging should be closed to indicate the feasible vehicle mode and the mode of allowing external charging. If is it not available to be completed in one single test, process two or more tests.

    4. The positive and negative terminals of the test object being connected to each other to create a short circuit. The resistance of the connection (including wiring) used to create short circuit should not exceeding 5mΩ.

    5. Keep short circuit until any of the following conditions are met and the test is completed.

    • The protective function of the test object works and the short circuit current is terminated.
    • After the temperature of the test object’s shell is stable (the temperature gradient is less than 4℃within 2h), the short circuit will continue for at least 1h.

    6. After testing, observe for 2h under room temperature.

    Main Features

    • Vacuum Interruption, avoid electric arc to occur damage of contactor.
    • Oxidation resistance condition of the main contact parts, ensure long operation time for high current and resistance.
    • Data Acquisition: Temperature, voltage and current acquisition channels (Available for multi-channels.)
    • Control Mode: Touch screen control + computer remote control + Remote controller.
    • Battery Short Circuit Test Equipment Standard
    • UL 2580

    Technical Parameters

    Model LEGSC-10000A LEGSC-15000A
    Max. Operating Current 10000A 16000A
    Max. Transient Current 12000A 16000A
    Temp. RangeAmbient Temperature
    Inner Resistance<1mΩ, <5mΩ, <10mΩ, <20mΩ, <50mΩ,<100mΩ (Optional)
    Control ModeClose PLC touch screen control + computer remote control + remote control
    External Dimension W700xD1050xH1830mm W700xD1050xH1830mm
    Explosion-proof Cabinet DimensionW2000xD3000xH2000mm (Option)
    Voltage Measurement Range0~1000V
    Short Circuit Response Time≦20ms
    Data InterfaceUSB, Data card, etc…
    Safety EquipmentVideo monitor system, explosion protection system, smoke exhaust system, smoke alarm Equipment, explosion proof lighting Equipment, etc.
    Data Acquisition ModuleIndependent remote acquisition and quarantine, multi-voltage/temperature/current acquisition channels ensure data accuracy. Acquisition frequency 100HZ
    Short Circuit MethodPneumatic + vacuum arc extinguishing
    Safety Alarm EquipmentElectric leakage, over-current protection, abnormal sound-light alarm, smoke alarm, dual protection system, etc.
    Testing FixtureCustomize according to actual testing condition
    • Large Current Battery Short Circuit Test Equipment LEGSC