Water Relux Tank/Steam Tank/Water Vessels/Recovery Tank
Send a request
Water Relux Tank/Steam Tank/Water Vessels/Recovery Tank
Description
Storage tanks are enclosed containers used to hold liquids, vapors, and gases at a pressure significantly higher or lower than the ambient pressure. They are widely used in various industries such as petrochemical, oil and gas, chemical, and food processing industries. Equipment such as reactors, flash drums, separators, and heat exchangers are examples of pressure vessels.
Water Relux Tank/Steam Tank/Water Vessels/Recovery Tank LEWRTSTWVRT are specially used in Petrochemicals production with high requirements for sealing.This is the Industrial high pressure chemical mixing tank reactor. It can be bear high pressure and high temperature, and heated by the jacket circulation. Permanent magnetic couplings offer a reliable alternative to conventional dynamic seals due to their contactless and leakage-free torque transmission in agitators and mixers.
Specification
Features
- Large scale industrial scale production;
- GB, ASME design and manufacture certificate.
- Max pressure: 200 bar; Max temperature up to 350 ℃;
- We offer carbon steel, stainless steel, or most exotic alloys such as Hastelloy, Monel, or Inconel;
- When the pressure is large, cladding plates could be considered, including base material for strength and clad material for anti-corrosion.
- Internal cooling coil, vent port, liquid / powder charging, dip tube, thermowell, safety rupture disc, pressure safety valve, flush bottom outlet, baffles, light & sight glass, handhole / manhole etc.
- We offer various internal and external finishes for our products.
- Lugs or floor stand leg support.


Parameters
| Norminal volume | 100L-200 m3 |
| Material | Carbon steel, SS, other alloy lined |
| Design pressure | -1-200 bar |
| Design temp. | -40-350°C |
| Base Thickness | 6~160mm |
| Clad Thickness | 3-10mm |
| Max Length | 16 m |
| Max Diameter | 6 m |
| Max weight | 200 tons |
| Shape | Vertical or horizontal |
| Head type | Semi-elliptical Dished type, Hemispherical, Flat type |
| Jacket | Dimpled, Half-pipe, Std. |
| Heating type | Oil electric heating; Oil heating; Steam heating |
| Note: If the diameter exceeds 6.000mm, it need to be fabricated on the site. If the unit weight exceeds 200tons or the total length exceeds40m, segmented transport and field welding will be required. | |