Pump LE06 Series Double Drive/Double Acting
Send a request
LE06
Pump LE06 Series Double Drive/Double Acting
Features:
- Choice of 4 ratios.
- Flows to 8.6 l/min.
- Choice of wetted materials.
- Output pressures to 50,000 psi (3448 bar).
- Drive pressure 3 to 150 psi (0.2 to 10.3 bar).
Performance and Specification Pump LE06 Series Double Drive/Double Acting:
Pump Model Code Max.Out Press. Actual Ratio Dis. /Cycle Max.Flow Inlet Port Outlet Port LE06-2D-70 11000psi 90:1 38ml 8.6l/min 1/2"FNPT 1/2"FNPT LE06-2D-120 19000psi 144:1 22ml 4.9l/min 1/2"FNPT 1/2"FNPT LE06-2D-200 33000psi 240:1 13.4ml 3.0l/min 1/2"FNPT 1/4"HF LE06-2D-300 50000psi 360:1 9ml 2.0l/min 1/2"FNPT 1/4 "HF * HF means female high pressure connection.
Dimensions (in.(mm):
* Air IN port is 3/4 female NPT for standard pumps.
Explain:
- All model code listed are standard.
- For angle pumps add “A” after the model codes.
- For Quick repair pumps add “-Q” after the model codes.
- For pumps with relief valve add “-R” after the model codes.
- For pumps with Viton seals add “-V” after the model codes.
- For pumps with Pressure switch valve add “-P” after the model codes.
- For cold area service add “-C” after the model codes.
- For liquid CO add “-C2” after the model codes.
- Other sizes, materials and types are available upon request.
Perfomance Curves: