✓ In-house manufacturing — Hastelloy C276 & titanium✓ Custom engineering & prototypes✓ API / ASTM · CSA · CRN · CE✓ Serving US, Canada, EU, Middle East, Central Asia, Africa & LatAm
Summary. The URC-628 Ultra Rock Centrifuge was the Coretest Systems high-speed rock-core centrifuge for capillary pressure and sample preparation, with an optional automation package: CCD line camera and strobe, automatic equilibrium detection and relative permeability from transient production. The Coretest Automated Core Centrifuge is the current machine for the same work: strobe and camera readout of every tube during rotation, drainage and inverted imbibition buckets on one rotor yoke, 3 × 1.5 in plugs at up to 13,000 rpm with published radii, RCF, temperature and utilities.

Why laboratories compare

Laboratories that built their capillary pressure workflow on a URC-628 look for a replacement when the machine, its drive or its automation computer reaches end of life, when spare parts or rotor recertification become hard to obtain, or when a second machine is needed to run the same method in parallel.

Coretest Automated Core Centrifuge vs URC-628

Coretest Automated Core CentrifugeURC-628
StatusCurrent production, configured to orderLegacy Coretest Systems model
Plug size1.5 in, up to 2 in long, 3 per run; 1 in rotor on request1 in or 1.5 in with the matching rotor
Maximum speed13,000 rpm, ±20 rpmSet by rotor: PIR20 (1 in) 20,000 rpm; PIR16.5 (1.5 in) 16,500 rpm
Plug face radii / RCFDrainage 43.0 / 93.8 mm, 17,720 ×g; imbibition 115.5 / 166.3 mm, 31,420 ×g at the outer faceNot stated in the catalogue
ReadoutStroboscope and camera image each measuring tube once per revolution; automatic level detectionOptional automation: computer-controlled CCD line camera and strobe; interface resolution 0.002 in
Data rateLogged against time and speed; equilibrium judged per step10 per second, or 1 per revolution below 600 rpm; logarithmic intervals during ramp
TestsDrainage and imbibition Pc, USBM cycle; production data for relative permeabilityDrainage and imbibition Pc, USBM/Amott, relative permeability from transient production
Temperature20 to 40 °C during tests; vacuum chamberNot stated in the catalogue
Control and software10 in touch screen; current industrial computer and acquisition softwarePC-based camera and acquisition software of its period
RotorsOwn rotor yoke with drainage and inverted imbibition bucket setsCompatible with earlier Rock Core Centrifuge rotors, buckets and accessories
Power220 V ±10 %, 50 Hz, single phase, 30 ANot stated in the catalogue

“Not stated” means the figure is not given in the manufacturer's published material; it does not mean the feature is absent.

What the differences mean in practice

Method transfer. The measuring principle is the same: a strobe freezes each tube, a camera reads the interface, and capillary pressure follows from speed, fluid densities and plug face radii. Your step tables are recalculated for the new radii so each step gives the same inlet-face capillary pressure as before.

Speed. The URC-628 PIR rotors reach 16,500 rpm on 1.5 in plugs and 20,000 rpm on 1 in plugs. The Automated Core Centrifuge runs to 13,000 rpm; its long imbibition arm (166.3 mm) keeps forced-imbibition capillary pressure high, but the highest drainage steps on tight rock should be checked against your schedule before ordering.

Rotors and accessories. The new machine uses its own rotor yoke and buckets. Existing PIR rotors and buckets are not carried over; plan plug holders and measuring tubes as part of the new scope.

Temperature and support. The new chamber is held at 20 to 40 °C under vacuum, and the electronics, drive and software are current production with spare parts and service from Coretest.

Who each is for

Coretest Automated Core Centrifuge
Laboratories replacing or adding to a URC-628 for 1.5 in imaging capillary pressure and USBM work, where the schedule stays within 13,000 rpm.
Keeping the URC-628 in service
Laboratories whose method depends on 16,500 to 20,000 rpm steps or on existing PIR rotors, and whose unit can still be maintained and its rotors recertified.

Moving a URC-628 method

Send your speed schedule, plug dimensions, fluid pair and a sample data file from the URC-628. Coretest converts each step to the speed that gives the same inlet-face capillary pressure on the new rotor, marks any step above 13,000 rpm and maps your output columns to the new export format.

Questions

Is the Automated Core Centrifuge a replacement for the URC-628?

Yes, for 1.5 in imaging capillary pressure, imbibition and USBM work up to 13,000 rpm. Steps that need higher speed on 1.5 in plugs, or 1 in plugs at 20,000 rpm, are not covered by the standard configuration.

Can I use my PIR rotors on the new machine?

No. The Automated Core Centrifuge has its own rotor yoke and bucket sets, supplied with the machine.

Can Coretest service my existing URC-628?

Send the serial number, the fault and photos of the rotor and drive. We will say what can be repaired and what should be replaced.

Replacing a URC-628?

Send the rock type, plug size, fluid pair, target capillary pressure and temperature. We will match them to a rotor and configuration.

Request a quoteDatasheet (PDF)

← Coretest Automated Core Centrifuge: description and specification

Also compare:

URC-628 is a legacy Coretest Systems model name, and PIR rotor designations are used here for identification only. Figures for the URC-628 are taken from the legacy Coretest catalogue and system description and are provided for engineering evaluation only; verify the configuration of your installed unit before planning a transfer.