Specification
Specification
| Plugs per run | 3 × 1.5 in, up to 2 in long (maximum 1.555 × 2.010 in); 1 in rotor on request |
| Bucket sets | drainage (standard) and imbibition (inverted), interchangeable on one rotor yoke |
| Plug face radii | drainage 43.0 / 93.8 mm; imbibition 115.5 / 166.3 mm |
| Speed | up to 13,000 rpm, ±20 rpm |
| RCF at outer plug face | 17,720 ×g drainage; 31,420 ×g imbibition |
| Readout | stroboscope and camera image each measuring tube during rotation; automatic level detection |
| Measuring tube | 6 mL, 0.1 mL graduation as standard; other volumes per project |
| Temperature | 20 to 40 °C during tests; vacuum chamber |
| Rotor life | 13,000 rpm for 1,000 runs or 2,500 h, then 10,000 rpm up to 5 years |
| Power | 220 V ±10 %, 50 Hz, single phase, 30 A |
| Size / weight | 700 × 900 × 1300 mm / 450 kg |
Guaranteed values are stated in the project-specific technical proposal.